Afla M1 HPLC Aflatoxin Testing System
Aflatoxin M1, a toxin found in milk, is derived from ingested aflatoxin. A known carcinogen, the detection of M1 is critical because this aflatoxin is found in milk, a major source of nutrition for infants, children, and adults. Throughout the world, there are significant regulations on the presence of M1 in dairy products. VICAM’s Afla M1™ HPLC is a fast flow column that delivers recovery rates from 75% to 95% depending on the sample.
Using monoclonal antibody-based affinity chromatography, Afla M1 HPLC is an HPLC-only test for the detection of aflatoxin M1 using immunoaffinity columns. Performed in less than 30 minutes, Afla M1 HPLC can measure levels of Afla M1 as low as 10 ppt and as high as 3 ppb.
An ideal cleanup step for any HPLC, Afla M1 HPLC has a long shelf life and provides precise numerical results in parts per billion or parts per trillion levels. The preferred test of laboratories around the world,no other test comes close for speed, quantification, and specificity.
Benefits
|
Here’s How Simple
|
Ordering Information |
|||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||
Subject to change without notice. © 1999, 2002, 2007 VICAM. Afla M1 HPLC is a trademark of VICAM. All VICAM products are protected by worldwide patents and trademarks.
VICAM
313 PLEASANT STREET
WATERTOWN, MA 02472
TEL: 800.338.4381, 617.926.7045
FAX: 617.923.8055
Web site: www.vicam.com
e-mail: vicam@vicam.com
The analytical methods presented in this data sheet have been researched and developed by VICAM to be used exclusively with Afla M1™ HPLC products.
These analytical methods have been validated in the VICAM laboratories to performto the specifications indicated in the Afla M1 HPLC procedures. The user assumes all risk in using Afla M1 HPLC analytical procedures and products.VICAM makes no warranty of any kind, expressed or implied,other than that Afla M1 HPLC products conform to VICAM’s printed specification and quality control standards. VICAM will, at its option, repair or replace any product,or part thereof,which proves to be defective in workmanship or material. VICAM’s undertaking to repair or service such products is exclusive and is in lieu of all other warranties whether written, oral, expressed,or implied, including any implied warranty of merchantability or fitness for a particular purpose.VICAM shall have no liability for anticipated or lost profits or any loss, inconvenience or damage whether direct, indirect, incidental, consequential or otherwise, to person or property, or for strict liability or negligence arising from or in connection with the use of these assay procedures or Afla M1 HPLC products.