Myco6in1™ LC/MS/MS Mycotoxin Testing System

Myco6in1 LS/MS/MS

With the proliferation of mycotoxin regulations around the world, many laboratories are finding the need to test for multiple toxins in a single commodity. VICAM, the proven leader in mycotoxin testing, has developed the first-of-its-kind multi-analyte column for simultaneous detection of aflatoxins, ochratoxin A, fumonisins, deoxynivalenol, zearalenone, and T-2 and HT-2 toxins. Optimized for use with LC/MS/MS detection—one of the most advanced, accurate, and widely used analytic methods in the world—VICAM's new Myco6in1™ LC/MS/MS enables laboratories to simultaneously determine multiple mycotoxins with unmatched levels of sensitivity, selectivity, and efficiency.

Myco6in1 LC/MS/MS is a quantitative method that unites VICAM’s proven monoclonal antibody-based immunoaffinity columns and powerful liquid chromatography combined with tandem mass spectrometry technology to provide precise numerical results. Simple and convenient to use, Myco6in1 LC/MS/MS requires only one sample and a single test run, so fewer materials are needed, and you can run more tests in less time—while still obtaining the reliable, accurate result you’ve come to expect from VICAM mycotoxin test kits.

Download a Datasheet for this Product (PDF)

Benefits

  • Versatile – For use with LC/MS/MS or HPLC
  • Accurate – Meets European Committee for Standardization (CEN) criteria for mycotoxin analysis methods
  • Comprehensive – Detects aflatoxins, deoxynivalenol,
    fumonisins, ochratoxin A, zearalenone, and T-2 and HT-2 toxins with one simple test
  • Convenient – Only one sample and one procedure
    required to detect multiple toxins
  • Durable – Long shelf life
  • Economical – One test provides results for multiple
    toxins, saving time and materials

Here’s How Simple Myco6in1 LC/MS/MS is to Use:

PBS Sample Extraction
(Extract A)
Grind and weigh sample
Add PBS
Shake and centrifuge
Separate and filter PBS extract
Methanol Sample Extraction
(Extract B)
Add methanol
Shake and centrifuge
Dilute and filter methanol:
PBS extract
Absorb and Elute
Pass extract B over column
Wash column
Pass extract A over column
Wash column
Elute toxins and collect in cuvette
Measure
Dry down and reconstitute eluate
Inject eluate into LC/MS/MS
Determine concentrations of each mycotoxin

Ordering Information

Cat. No. Description
100000176 Myco6in1™LC/MS/MS Columns
(25 per box)
G1113  Phosphate Buffered Saline, 10X concentrate (150 mL)
G4033  Micro-pipettor, 1.0 mL
20050  Graduated Cylinder, 50 mL
20100  Digital Scale with AC Adapter
20250  Graduated Cylinder, 250 mL
20656  Micro-pipette Tips for 1 mL
Micro-pipettor (100)
20700  Wash Bottle, 500 mL
21010  Cuvette Rack
21020  Single Position Pump Stand*
34000  Disposable Cuvettes (250 per pack)
35016  Methanol, HPLC Grade (4 x 4 L)
36010  Disposable Plastic Beakers
(25 per pack)
36020  Filter Funnel, 65 mm (10 per pack)
Also required; must be sourced locally:
Acetic Acid, Glacial (HPLC Grade)
Ammonium Acetate (mass spectrometry grade)
Centrifuge Capable of 3000 x g
Relative Centrifugal Force
Distilled, Reverse Osmosis, or Deionized Water
Orbital Shaker
Whatman GF/A Microfibre Filters
 
* Multiple position pump stands available.

Subject to change without notice.
©2008 VICAM. Myco6in1™ LC/MS/MS is a trademark of VICAM.
All VICAM products are protected by worldwide patents and trademarks.

VICAM, a Waters Business
34 MAPLE ST.
MILFORD, MA 01757
TEL: 800-338-4381, 508-482-4935
FAX: 508-482-4972
Web site: www.vicam.com
e-mail: vicam@vicam.com

The analytical methods presented in this data sheet have been researched and developed by VICAM to be used exclusively with Myco6in1™ LC/MS/MS products. These analytical methods have been validated in the VICAM laboratories to perform to the specifications indicated in the Myco6in1 LC/MS/MS procedures.

The user assumes all risk in using Myco6in1 LC/MS/MS analytical procedures and products. VICAM makes no warranty of any kind, expressed or implied, other than that Myco6in1 LC/MS/MS products conform to VICAM’s printed specification and quality control standards. VICAM will, at its option, repair or replace any product, or part thereof, which proves to be defective in workmanship or material. VICAM’s undertaking to repair or service such products is exclusive and is in lieu of all other warranties whether written, oral, expressed, or implied, including any implied warranty of merchantability or fitness for a particular purpose. VICAM shall have no liability for anticipated or lost profits or any loss, inconvenience, or damage whether direct, indirect, incidental, consequential, or otherwise, to person or property, or for strict liability or negligence arising from, or in connection with, the use of these assay procedures or Myco6in1 LC/MS/MS products..

Back to Top

Back to Section Index