OchraTest Testing System
Ochratoxin A is a mycotoxin produced by the fungus Aspergillus ochraceous and also by several species of Penicillium. Ochratoxin A has been known to cause kidney damage in animals and is considered a carcinogen. Using monoclonal antibody-based affinity chromatography, OchraTest™ from VICAM is the trusted ochratoxin test that produces precise numerical results.
OchraTest is safe and simple. It can be performed in less than 10 minutes and requires no special skills. Results may be recorded using a digital fluorometer readout or automatic printing devices.
OchraTest is also ideal as the cleanup step for any HPLC analysis. Unaffected by heat or humidity, OchraTest has a long shelf life. With OchraTest, you have the best of all worlds: sensitivity, simplicity, and speed—quick tests for parts per billion levels. In fact, no other test comes close for speed, quantification, and economy.
Benefits
*excludes preparation and extraction |
Here’s How Simple
|
Ordering Information |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Subject to change without notice. ©1998, 2002, 2007 VICAM. OchraTest™ is a trademark of VICAM. All VICAM products are protected by worldwide patents and trademarks.
VICAM
313 PLEASANT STREET
WATERTOWN, MA 02472
TEL: 800-338-4381, 617-926-7045
FAX: 617-923-8055
Web site: www.vicam.com
e-mail: vicam@vicam.com
The analytical methods presented in this data sheet have been researched and developed by VICAM to be used exclusively with OchraTest™ products. These analytical methods have been validated in the VICAM laboratories to perform to the specifications indicated in the OchraTest procedures.
The user assumes all risk in using OchraTest analytical procedures and products. VICAM makes no warranty of any kind, expressed or implied, other than that OchraTest products conform to VICAM’s printed specification and quality control standards. VICAM will, at its option, repair or replace any product, or part thereof, which proves to be defective in workmanship or material. VICAM’s undertaking to repair or service such products is exclusive and is in lieu of all other warranties whether written, oral, expressed, or implied, including any implied warranty of merchantability or fitness for a particular purpose. VICAM shall have no liability for anticipated or lost profits or any loss, inconvenience or damage whether direct, indirect, incidental, consequential or otherwise, to person or property, or for strict liability or negligence arising from or in connection with the use of these assay procedures or OchraTest products..