Salmonella Screen / SE Verify Microbiological Testing System

SE Verify

Results In Less Than 24 Hours

Being sure that food is safe for consumers is a major concern of the food industry. For this reason, tests for Salmonella
enteritidis
are used throughout the food industry to ensure quality. These tests have generally been difficult to conduct and
have required a long wait between taking samples and obtaining results. Now you can rule out the presence of Salmonella
enteritidis
using VICAM technology that is faster and still as sensitive as conventional methods. VICAM's SE Verify achieves this performance with breakthrough technology that will create the opportunity for new levels of food safety. Users of VICAM's SE Verify tests enjoy both speed and simplicity of advanced technology, secure in the confidentiality provided by tests run in-house or at trusted labs.

Overview

  • The procedure is simple. Magnetic beads, coated with antibodies that bind to Salmonella species are used to isolate Salmonella and Salmonella enteritidis from samples.

Simple Use

  • Prepare sample
  • Add antibody coated Salmonella Screen magnetic beads to prepared sample in vials and rotate vials
  • Isolate magnetic beads with Salmonella from sample by drawing magnetic beads to a magnet
  • Wash magnetic beads with buffer
  • Spread beads on plates and incubate for 16-22 hours
    • If no positive colonies (black) are detected, the result is negative and the test is done
    • If positive colonies appear, perform SE latex agglutination test to verify Salmonella
    • No agglutination means the test is negative for S. enteriditis
    • Positive agglutination means S. enteriditis, S. bledgam, S. Moscow or some types of S. dublin are present

Features & Benefits

  • Confidential - Can be performed in-house
  • Rapid - Results in less than 24 hours
  • Simple - Little training required
  • Sensitive - Equal to conventional methods
  • Economical - Cost effective

Ordering Information

Cat. No. Description
SAL-2000A

Salmonella Screen and SAL Verify complete kit for raw steak, shell eggs, fish meal and poultry feed - sufficient for 100 screen and 20 verify tests - contains:

  • Food Enrichment Medium (2x500g)
  • Plus "Items Common to All Kits" as listed below
SAL-2000B

Salmonella Screen and SAL Verify complete kit for raw pork, raw ground beef, raw sausage, raw chicken, cooked chicken, frozen egg yolk, frozen whole egg, frozen plain egg, frozen egg white and hen house drag swab environment samples - sufficient for 100 screen and 20 verify tests - contains:

  • Environmental Enrichment Medium (7x1 gallon)
  • Iodine Solution (7x160mL)
  • Plus "Items Common to All Kits" as listed below
SAL-2000C

Salmonella Screen and SAL Verify complete kit for processing environment and chicken rectal swab samples - sufficient for 100 screens and 20 verify tests - contains:

  • Food Enrichment Medium (1x100g)
  • D/E Medium (5x20 tubes)
  • Environment Swabs (5x20 swabs)
  • Plus "Items Common to All Kits" as listed below
Cat. No. Description
Items Common to All Kits
 
  • Capture Vials (1x100 vials)
  • Salmonella Screen Immunobeads (5x1 vial)
  • Test Cards (2x1 card)
  • XLD Plates (10x10 plates)
  • Agglutination Buffer (+) Reference (1x5.0mL)
  • Reaction Buffer (1x5.0mL
  • Agglutination Buffer (+) Reference (1x1.0mL)
  • SE Verify Latex Beads (1x0.7mL
  • Inoculation Loops (10x10 loops)
  • Filter Paper (5x20 filters)
  • Capture Buffer Concentrate (5x20mL)
  • Glass Spreaders (4x25 spreaders)
  • Salmonella Screen/Salmonella Verify Instruction Manual
Capital Equipment
LIS-109-000  Capture Vial Rotator
LIS-113-000  Stomacher
LIS-114-000  Electrapette
LIS-114-300  Magnetic Slider Rack

Subject to change without notice.
© 2001 VICAM LP. Salmonella Screen/SE Verify™ is a trademark of VICAM LP. VICAM products are protected by worldwide patents and trademarks.

VICAM
313 PLEASANT STREET
WATERTOWN, MA 02472
TEL: 800-338-4381, 617-926-7045
FAX: 617-923-8055
Web site: www.vicam.com
e-mail: vicam@vicam.com

The analytical methods presented in this data sheet have been researched and developed by VICAM to be used exclusively with Salmonella Screen/SE Verify™products.

These analytical methods have been validated in the VICAM laboratories to perform to the specifications indicated in the Salmonella Screen/SE Verify procedures.

The user assumes all risk in using Salmonella Screen/SE Verify analytical procedures and products. VICAM makes no warranty of any kind, express or implied, other than that Salmonella Screen/SE Verify products conform to VICAM’s printed specification and quality control standards. VICAM will at its option repair or replace any product or part thereof which proves to be defective in workmanship or material. VICAM’s undertaking to repair or service such products is exclusive and is in lieu of all other warranties whether written, oral, expressed, or implied, including any implied warranty of merchantability or fitness for a particular purpose. VICAM shall have no liability for anticipated or lost profits or any loss, inconvenience or damage whether direct, indirect, incidental, consequential or otherwise, to person or property, or for strict liability or negligence arising from or in connection with the use of these assay procedures or Salmonella Screen/SE Verify products.