Series-4EX Fluorometer

ZearalaTest WB Affinity Column

The VICAM Series-4EX Fluorometer™ is simple to operate. At the touch of a button, you identify the mycotoxin to be measured. After isolating the mycotoxin using VICAM’s immunoaffinity column, insert the sample into the fluorometer. It then reads the fluorescence and displays results. Simply and efficiently, the Series-4EX is able to measure total mycotoxin levels in samples prepared using VICAM’s mycotoxin columns.

Additional features of the Series-4EX also add to the simplicity of operation. An internal clock monitors the time of its last calibration, alerting you when a new calibration is needed. The Series-4EX also uses an illuminated 2-line display to prompt you through testing steps.

The VICAM Series-4EX Fluorometer accurately measures down to extremely low PPT concentrations of mycotoxins in samples prepared using VICAM’s columns. Expanded data storage capacity allows for storage of all the VICAM mycotoxin test protocols and calibration levels, as well as up to 200 test results. Stored testing protocols provide for a digital readout in PPM, PPB, PPT, mg/kg, μg/kg, or ng/kg concentration units without requiring any conversion.

Download a Datasheet for this Product (PDF)

Benefits

  • Simple – Choose test, insert sample, read results
  • Comprehensive – Stores up to 20 test protocols, 375 test results, and calibration parameters for each test protocol
  • Accurate – Digital readout in PPM, PPB, PPT, mg/kg, μg/kg or ng/kg
  • Durable – Over 200,000 tests without a lamp change
  • Stability – Extended period without a lamp change
  • Versatile – Can be used over a wide range of ambient conditions

Here’s How Simple the Series-4EX Fluorometer is to Use:

Prepare Sample
Isolate mycotoxin using a VICAM immunoaffinity column
Run Test
Select test protocol
Calibrate fluorometer
Insert sample to be measured
Run test
Read Results
Test results can be displayed electronically, printed, or downloaded to a computer

Ordering Information

Cat. No. Description
G8000 VICAM Series-4EX Fluorometer™
 

Features of the VICAM Series-4EX Fluorometer include:

Expanded Internal Memory
Stores up to 20 test protocols
Stores up to 375 test results
Integral Printer
Detailed copies of test results
Printout of cumulative test data
Record of system and protocol status
Allows for Chinese characters and graphics
Temperature and Voltage Compensated Electronics
Measurement accuracy over a wide range of ambient conditions
Long Term Stability
Extended period between calibrations
Long-life Xenon Lamp
Over 200,000 tests without lamp changes
Edit Test and Create Test Capability
Custom additions and changes to test protocols by keypad entry
USB Port Interface
Easy update of system software, no more ROM card to replace – obsolescence is eliminated
Enclosed Cabinet
Dust contamination minimized
Advanced CPU
Faster microprocessor controller chip allows for self-diagnosis checks to verify system functioning within required parameters
External Power Supply
Guarantees UL and international voltage compatibility
Can be used in any domestic or International location

Subject to change without notice.
©2006 VICAM. Series-4EX Fluorometer is a trademark of VICAM.
All VICAM products are protected by worldwide patents and trademarks.

VICAM, a Waters Business
34 MAPLE ST.
MILFORD, MA 01757
TEL: 800-338-4381, 508-482-4935
FAX: 508-482-4972
Web site: www.vicam.com
e-mail: vicam@vicam.com

The analytical methods presented in this data sheet have been researched and developed by VICAM to be used exclusively with Series-4EX Fluorometer™ These analytical methods have been validated in the VICAM laboratories to perform to the specifications indicated in the Series-4EX procedures.

The user assumes all risk in using Series-4EX analytical procedures and products. VICAM makes no warranty of any kind, expressed or implied, other than that the Series-4EX Fluorometer conforms to VICAM’s printed specification and quality control standards. VICAM will at its option repair or replace any product or part thereof which proves to be defective in workmanship or material. VICAM’s undertaking to repair or service such products is exclusive and is in lieu of all other warranties whether written, oral, expressed, or implied, including any implied warranty of merchantability or fitness for a particular purpose. VICAM shall have no liability for anticipated or lost profits or any loss, inconvenience or damage whether direct, indirect, incidental, consequential or otherwise, to person or property, or for strict liability or negligence arising from or in connection with the use of these assay procedures or the Series-4EX Fluorometer.